Proscenium Width (max) | 10.100m |
Proscenium Height (max) | 6.830m |
Top Bar Dead | 8.770m |
Depth of Stage |
8.600m |
Wings Width Stage Left Down Stage (approx) | 4.800m |
Wings Width Stage Left Up Stage (approx) | 2.750m |
Wings Width Stage Right Down Stage (approx) | 1.780m |
Wings Width Stage Right Up Stage (approx) |
3.280m |
Height Under Gallery Stage Left | 2.840m |
Height Under Gallery Stage Right |
2.840m |
Forestage/Orchestra Pit Width* | 12.500m |
Forestage/Orchestra Pit Depth* | 2.200m |
Forestage has a curved front edge* - add 1.000m at centre | |
Auditorium Floor to Stage | 0.880m |
Stage to FOH Sound | 10.000m |
Stage to Box | 12.000m |
Box to FOH Sound | 2.000m |
Multicore length to reach FOH Sound | 20.000m |
Multicore length to reach Box | 25.000m |
Get In Height | 2.730m |
Get in Width | 2.450m |
Diagonal (Max Flat) | 3.700m |
Some storage available in scene dock. Venue has no safety curtain. Crossover trough scene dock or under stage. |
*Advise at contract stage if using pit or forestage as this affects wheelchair seating
Board | Strand LBX Fully Loaded (125 Channel Max) |
Control | DMX 512 with outlets all over the place Some outlets are not yet functional |
Dimming | Strand LD90 Digital Dimming 96 circuits at 2.5kW 12 circuits at 5.0kW and 12 independent switch circuits all over the place, controlled from panel in Control Room |
Follow Spots | 2 Robert Juliat 'Foxie' 700W MSD |
Luminaires | 8 Strand Cantata 11/26 1200W Profiles 8 Strand Cantata 18/32 1200W Profiles 6 Strand Brio 600W Profiles 24 Strand Cantata 1200W Fresnels with Barn Doors 20 Par 64 Cans all with CP62 Lamps 4 Par 64 Chrome Floor Cans 6 Strand Nocturne 1000W Floods 10 Strand Coda 4 Compartment 500W CYC Floods |
Other Stuff | 4 Cantata Iris 4 Doughty Squab Lighting Stand 2 Double Extension Lighting Stand (max 3.800m) Cantata 'A' & 'B' sized Gobo Holders Quantity of 15A cable |
Power | 100A 3-phase supply available Stage Left (bare ends or lugs) |
Rigging | There are four winch bars on stage for lighting with a 250kg safe working load. All other bars are hemp with a 100kg safe working load. There are 12 6-way IWBs to facilitate rigging. The FOH lighting bridges should pose no problems. |
Piano | Yamaha Baby Grand |
Desk | Alan and Heath GL2200 |
Speakers | L/C/R System, Pre-programmed using Martin Audio Loudspeakers |
Mixing Position | Standard position in Control Room with opening window. Alternative location at rear of Stalls Please advise at contract stage if this is required Cable access via 0.200m drainpipe from Stage Left, Stage Right and Control Room |
Tie Lines | 24 Speaker lines 24 Audio lines 37 Microphone lines (12 Tie lines to Pavilion) The lines appear in Orchestra Pit and all other conceivably required areas! |
Toys | 2 EV SX 200 Wedge Foldback Speakers Effects Rack with: Denon DN100F CD Player Twin Channel Graphic Equaliser Yamaha SPX990 Digital FX Processor 4 Shure SM58 General Purpose Microphones 2 Tabletop Microphone Stands 6 Microphone Stands 2 Telescopic Microphone Stands |
Communications | 6 Headsets to all areas |
Power | Dedicated 13A Socket Outlets throughout building 63A Busbar Outlet at Stage Left All sound outlets are on the same electrical phase Only designated outlets may be used. This is to allow the Fire Alarm to turn off the sound system and is NOT NEGOTIABLE! |
All measures taken from Front of Stage | |
House Tabs | 0.700m |
Proscenium Masking | 1.000m |
Hemp 1 | 1.200m |
LX 1 | 1.400m |
Cinema Screen | 2.050m |
Hemp 2 | 2.500m |
Hemp 3 | 2.700m |
Hemp 4 | 2.900m |
LX 2 | 3.300m |
Hemp 5 | 3.700m |
Hemp 6 | 3.900m |
Hemp 7 | 4.100m |
LX 3 | 4.500m |
Hemp 8 | 4.900m |
Hemp 9 | 5.100m |
LX 4 | 5.500m |
Hemp 10 | 5.900m |
Hemp 11 | 6.300m |
Hemp 12 | 6.700m |
Hemp 13 | 7.100m |
Hemp 14 | 7.500m |
Get In | There is good access for a truck of any size to back onto the Scene Dock. Once off the truck access to the Stage is flat but we do not own a ramp to unload the truck. The Scene Dock faces out to sea - beware bad weather! |
Parking | The Scene Dock must not be blocked. Parking is available in nearby public (Pay & Display) car parks.Please note that these are very busy during the summer season. |
Capacity | The Auditorium seats 483. In the interest of safety or on a Fire Officer's advice, the Theatre reserves the right to limit the number of people using the Stage. |
Sound | The Theatre fire alarm must be able to disconnect the PA. Only designated power supplies may be used - this is NOT NEGOTIABLE, sorry. |
Smoke | Any use of smoke, pyrotechnics, haze or naked flame MUST be approved by the Duty Stage Manager BEFORE USE. |
Extras | Our closest theatrical supplier is Stage Electrics, Exeter (about 50 miles away). Most equipment is therefore hard to get at short notice. We will gladly organise hires and contra charges accoprding to contractual arrangements. The following items are often available to hire locally: Jem ZR20 Smoke Machine Sony Domestic Mini Disc Various lanterns Pyro systems Sound equipment Please for prices and availability. |
Faces of the Theatres